


|
|
| Mission Critical Equipment Serving Public Safety Professionals & Agencies |
Fax 315-626-6606 |
Simulaids Trauma Randy Complete Kit is an essential all-in-one medical training tool engineered for realistic trauma stabilization, field extrication, and tactical casualty care. Built specifically for first responders, military personnel, and medical trainees, this comprehensive system prepares field teams for the high-stakes pressure of halting severe hemorrhages and managing catastrophic trauma in real time.
At the center of this package is the rugged 6'1" Large Body Rescue Randy manikin. Weighing 55 lbs, it features a durable vinyl skin over a steel frame and 4,100 lb. test plastic-coated cables. The body is fully articulated to mirror human weight distribution, allowing for life-like patient handling and positioning across confined spaces, mock vehicle crashes, or rugged outdoor rescue environments.What elevates this complete kit is the full suite of Flash Moulage upgrades. It includes the Chest Overlay, Arm, Leg, and Head Flash Moulage setups. This provides a highly accurate external blood management system powered by a domed foot pump. Trainers can rapidly deploy realistic bleeding or non-bleeding injury presentations, including deep packing wounds, shallow lacerations, a third-degree burn, an arm amputation with a brachial tourniquet point, a femoral artery leg overlay, and pressure-controlled jaw and forehead bleed tubes.
Each kit comes with authentic TrueClot blood simulant concentrate, specialized hemostatic gauze, and clotting solutions to mimic real-world emergency scenarios accurately.Maintenance is remarkably straightforward. The specialized design utilizes no sticky glues or adhesives, ensuring cleanups require nothing more than flushing out the lines, rinsing, and drying the vinyl. is constructed to meet the training requirements of medical staffs. It is designed to provide a life-like trauma stabilization experience to trainees, so they can handle real-life scenarios in medical facilities. When a traumatized person is admitted, it is vital for the attending team to stop the blood flow in time to prevent fatality. By using this kit, medical trainees can get familiar in the treatment of traumatized patients and learn how to stem the flow of blood. This kit is low on maintenance as it does not use adhesives or glue in its construction. It can be cleaned conveniently by flushing the lines, rinsing, and drying.
Kit Includes:
149-1431: Rescue Randy 55 lbs Large Body
808-6000: Overlay Flash Moulage
808-6001: Arm Flash Moulage
808-6002: Leg Flash Moulage
808-6003: Head Flash Moulage
A: This comprehensive bundle includes the 6'1" Large Body Rescue Randy manikin (55 lbs), alongside the full Flash Moulage Upgrade system. This system features chest, arm, leg, and head overlays, a specialized fluid delivery system with a domed foot pump, a gallon of TrueClot Blood Simulant Concentrate, simulant hemostatic gauze, clotting solution, and a line-flushing syringe.
A: No. The Trauma Randy Flash Moulage System utilizes an innovative overlay design that securely wraps around the manikin's large-body frame without any sticky glues. This layout allows instructors to seamlessly transition between scenarios without scraping away residue.
A: The kit is built to simulate a wide variety of lifelike tactical injuries. It features one deep bleeding wound optimized for realistic gauze packing, three shallow bleeding lacerations, a massive third-degree burn overlay, an arm amputation with a functional brachial tourniquet point, a femoral artery leg overlay, and dedicated jaw and forehead bleeding tubes.
A: The system relies on a manual, domed foot pump paired with a gravity feed tank. This allows an instructor to safely regulate blood flow pressure manually, simulating arterial spurts or steady venous pooling based on the training curriculum's demands.
A: Yes. The underlying Rescue Randy manikin features a rugged steel frame wrapped in tough vinyl, supported by 4,100 lb. test plastic-coated cables. It is fully articulated at the joints to mimic natural human weight distribution during complex extrications.
A: Yes. When using the included TrueClot Blood Simulant alongside the simulant hemostatic gauze, a realistic chemical reaction creates life-like blood clots. This provides instant visual and physical feedback to trainees executing proper wound packing techniques.
A: Absolutely. The inclusion of true-to-life tourniquet application points, realistic junctional zones, and packable hemorrhagic wounds makes it a perfect tool for TCCC and TECC (Tactical Emergency Casualty Care) training applications.
A: TrueClot simulant products are completely non-toxic and water-soluble. While it mimics the viscosity and color of human blood perfectly, it washes clean out of most fabrics and rinses away easily with water.
A: Cleaning is streamlined because the system uses no messy adhesives. Instructors simply need to clear the internal fluid lines using the included flushing syringe, rinse the exterior vinyl overlays with water, and let all components air-dry before packing them away.
A: No. According to the official operating guidelines from Simulaids, you must never suspend the manikin solely by its built-in rear eye-hook. For vertical, high-angle, or ladder rescue drills, the manikin must be secured inside a specialized rescue harness.